• en Language
  • fi Language
https://assets.liunedoor.com/upload/kuvat/KOOLARI_HTL3040_1_HTL30x40.jpg
https://assets.liunedoor.com/upload/kuvat/KOOLARI_HTL4030_2_HTL30X40.jpg

HTL30x40

Steel profiles for wall framing and boarding, width 40mm, hight 30mm

0,00

Loading...
Loading...

Total Price:

0,00

Manufacturing 

Cold-formed hot-dip galvanized open profiles made with roll forming.

Intended Use

Multiple applications as a jointing profile (facades, external and internal walls, ceilings, suspended ceilings, floors, supports, cladding). Reinforcement profiles can be used in facade renovation and new construction projects. Coating work is considerably faster and the long-term durability of the anti-corrosion frame is the best on the market.

Measurements

Standard length 3300mm but can be manufactured according to the requirements of the object to the specified size. The accuracy of the measurement in the profile is +/- 3 mm.

Attachment

Use a suitable attachment style when attaching the hat list for example a fastener. Galvanized fasteners are most often used in interior construction, and we recommend stainless steel fasteners for exterior construction. Check the suitability of the attachments with the site designer.

It is a good idea to drill pre-holes in the hat rail if the fasteners are not drill screws. Suitable for steel joints are e.g. drilling screws.  NOTE: There is no pre-perforated mounting holes in Hat furrings.

Make sure that the screw does not overturn and engages its base. Check the attachment of the discs according to the disc manufacturer's instructions.

The cutting of the profiles can be done with a carbide blade for a circular saw, an angle grinder or a hacksaw.

In end joints, an exercise interval should be left at the end of the profiles. This prevents changes due to possible heat movements.

Perforation

Ventilation perforation is also available for Koolari ® profiles, in which case Ventilated Hat Furring (HTL Ruode) is used as the product code. 

Sound insulation

The sound insulation of the structure must be considered on a case-by-case basis.

In case of a fire

Hat lists do not participate in the event of a fire, and do not increase the longevity of the fire and will not drip flammable substances. Fire behavior is classified in category A1. The profiles can be used to slow down and prevent the spread of fire, for example in the ventilation gap. HTL Palo / HTLP is used as the product code for the fire profile used in ventilated facades.

Packaging

Truck bundle (eg 200 pcs.), Plastic strap fastening at both ends, no protective plastic.

Storage

Allowed outdoor storage, bundles are lifted off the ground on wooden bars. Strips are placed between the bundles and the bundles are preferably tilted so that the rainwater drains off the surfaces.

Recycling

100% recyclable material. If necessary, each profile can be removed and reused. The steel frame can be recycled at the end of the building's service life.

EPD -report

EPD Koolari

More information and Dop

HTL30x40

  • 0,000€/ (alv 0%)
  • Weight: /
  • Weight: kg/
  • Estimated delivery: week(s)